The table below describes the timing connector pin assignments, followed by a description of each pin group in the table Timing Module Connector Pin Groups .
|
Pin |
Name |
Function |
Pin |
Name |
Function |
|
1 |
GND |
Ground |
2 |
EXT0 |
External event line # 0 (LSB) |
|
3 |
EXT1 |
External event line # 1 |
4 |
EXT2 |
External event line # 2 |
|
5 |
EXT3 |
External event line # 3 |
6 |
GND |
Ground |
|
7 |
EXT4 |
External event line # 4 |
8 |
EXT5 |
External event line # 5 |
|
9 |
EXT6 |
External event line # 6 |
10 |
EXT7 |
External event line # 7 |
|
11 |
GND |
Ground |
12 |
EXT8 |
External event line # 8 |
|
13 |
EXT9 |
External event line # 9 |
14 |
EXT10 |
External event line # 10 |
|
15 |
EXT11 |
External event line # 11 |
16 |
GND |
Ground |
|
17 |
EXT12 |
External event line # 12 |
18 |
EXT13 |
External event line # 13 |
|
19 |
EXT14 |
External event line # 14 |
20 |
EXT15 |
External event line # 15(MSB) |
|
21 |
GND |
Ground |
22 |
|
Spare |
|
23 |
|
Spare |
24 |
GND |
Ground |
|
25 |
XPAUSE |
External override pause command |
26 |
GND |
Ground |
|
27 |
XTRIG |
External override run command |
28 |
GND |
Ground |
|
29 |
ORUN |
Run Indication |
30 |
GND |
Ground |
|
31 |
XCLK |
External Clock input |
32 |
GND |
Ground |
|
33 |
XSTB |
External Strobe input |
34 |
GND |
Ground |
|
35 |
XCEN |
External Clock Enable |
36 |
GND |
Ground |
|
37 |
|
Spare |
38 |
GND |
Ground |
|
39 |
OCLK |
Clock Output |
40 |
GND |
Ground |
|
41 |
OSTB |
Strobe Output |
42 |
GND |
Ground |
|
43 |
|
Spare |
44 |
GND |
Ground |
|
45 |
BCLK |
Spare B Clock |
46 |
GND |
Ground |
|
47 |
|
Spare |
48 |
|
Spare |
|
49 |
|
Vcc (+5v) |
50 |
|
Vcc (+5V) |
Timing Module Connector Pins
|
Name |
I/O |
Function |
|
EXT 1-16 |
Input |
External event lines |
|
XPAUSE |
Input |
When set to low, the board is forced to the PAUSE state. Only if the board is armed. If both (XTRIG and XPAUSE) are low and the board was armed, the board will toggle between the RUN state and the PAUSE state every clock cycle. |
|
XTRIG |
Input |
When set to low, the board is forced to the RUN state. Only if the board is armed. If both (XTRIG and XPAUSE) are low and the board was armed, the board will toggle between the RUN state and the PAUSE state every clock cycle. |
|
ORUN |
Output |
When low, the board is in the RUN state. |
|
XCLK |
Input |
External clock |
|
XSTB |
Input |
External strobe |
|
XCEN |
Input |
External clock enable. When low, the board is forced to use the external clock. The external clock must be present before this line is set to low. If this line is set to low before arming the board, it may cause improper operation of the board. |
|
OCLK |
Output |
Clock output |
|
OSTB |
output |
Strobe output |
|
BCLK |
output |
B clock output |