Applies To
GC5050, GX5050, GX5150, GX5280, GX5290, GX5290e, GX5295, File
Purpose
Returns the Master board external event lines source.
Syntax
DioGetTriggerXEventSource (nMasterHandle, pnSource, pnStatus)
Parameters
Name |
Type |
Comments |
nMasterHandle |
SHORT |
Master or File board handle. |
pnSource |
PSHORT |
Values are: 0 The source is external event lines (default). 1 The source is the X register. |
pnStatus |
PSHORT |
Returned status: 0 on success, negative number on failure. |
Comments
The function is used to simulate external event lines. When nSource is 1, the X register value is used instead of external event lines on trigger, pause and conditional commands in the running vector. DioWriteXRegister can be used to set the value of the X register.
Example
The following example returns the X register trigger source:
SHORT nStatus, nSource;
DioGetTriggerXEventSource (nMasterHandle, &nSource, &nStatus);
See Also
DioSetupTriggerXEventSource, DioWriteXRegister, DioSetupTriggerMode