GX5055, GX5295, File.
Sets the channel input load states.
DioSetupInputLoadState (nHandle, nChannelListMode, nCountOrFirstChannel, panChannelList, nLastChannel, nState, pnStatus)
Name |
Type |
Comments |
nHandle |
SHORT |
DIO Master handle, Slave handle or File board handle. |
nChannelListMode |
SHORT |
Channel list mode dictates how nCountOrFirstChannel and panChannelList parameters are used. Channel list mode options are as follows:0 DIO_CH_LIST_MODE_ARRAY_OF_CHANNELS: The user specifies an array of channels where nCountOrFirstChannel is the number of elements in the list array and panChannelList is an array contains the channels numbers. In this mode nLastChannel is ignored.1 DIO_CH_LIST_MODE_ALL_BOARD_CHANNELS: Apply the settings to all the board’s channels associated with this board handle. In this mode nCountOrFirstChannel, panChannelList and nLastChannel variavles are ignored.2 DIO_CH_LIST_MODE_ALL_DOMAIN_CHANNELS: Apply the settings to all the channels in the domain, e.g. if there are two boards in the domain (Master and a Slave), then all 64 channels will be set. In this mode nCountOrFirstChannel, panChannelList and nLastChannel variavles are ignored.3 DIO_CH_LIST_MODE_RANGE_OF_CHANNELS: Apply settings to a range of channels where nCountOrFirstChannel is the first channel number and nLastChannel is the last channel number. In this mode panChannelList variavle is ignored. |
nCountOrFirstChannel |
SHORT |
If nChannelListMode parameter is set to DIO_CH_LIST_MODE_ARRAY_OF_CHANNELS, then it is specifying the number of elements in the panChannelList array parameter.If nChannelListMode parameter is set to DIO_CH_LIST_MODE_RANGE_OF_CHANNELS, then it is specifying the first channel number to apply the settings to,otherwise it is ignored and should set to zero.GxChannel number in the DIO domain, each DIO board adds 32 I/O channels. I/O channels number range is 0-991 (1 master and 30 slaves).Gx5295: Each DIO board adds 4 Auxiliary channels, Auxiliary channels number range is 0-123 (1 master and 30 slaves). |
panChannelList |
PSHORT |
Array of channels numbers. Channels numbers can be from 0 to the last channel in the domain. E.g., if the domain has two boards then the last channel is 63.This parameter is only used if nChannelListMode parameter is set to DIO_CH_LIST_MODE_ARRAY_OF_CHANNELS, otherwise is should be passed as NULL.Channel number in the DIO domain, each DIO board adds 32 I/O channels. I/O channels number range is 0-991 (1 master and 30 slaves).Gx5295: Each DIO board adds 4 Auxiliary channels, Auxiliary channels number range is 0-123 (1 master and 30 slaves). |
nLastChannel |
SHORT |
If nChannelListMode parameter is set to DIO_CH_LIST_MODE_RANGE_OF_CHANNELS, then it is specifying the last channel number to apply the settings to,otherwise it is ignored and should set to zero.Channel number in the DIO domain, each DIO board adds 32 I/O channels. I/O channels number range is 0-991 (1 master and 30 slaves).Gx5295: Each DIO board adds 4 Auxiliary channels, Auxiliary channels number range is 0-123 (1 master and 30 slaves). |
nState |
SHORT |
Load states:0. DIO_LOAD_DISCONNECTED: Load is not connected.1. DIO_LOAD_CONNECTED: Load is connected. |
pnStatus |
PSHORT |
Returned status: 0 on success, negative number on failure. |
GX5055:
The function enables all the loads to be applied to the specified input channels (constant source and the resistive load). When the load is enabled there is a ~40Ohm resistor in between the input And the loads.
Each channel has an independent load with the following capabilities:
● Channels’ Input constant source and sink currents up to 24 mA – DioSetupInputLoadCurrent function.
● Maintain high impedance over a wide voltage.
● Separate high and low clamping (commutating) voltages – DioSetupInputLoadCurrentVoltageClamps function.
● Channels’ Input Resistive load options - DioSetupInputLoadResistance function.
With independent high and low clamping (commutating) voltages, the source and sink currents each have their own threshold voltage. If the voltage on the input, when the load is activated, is between the two clamping voltages, the load will remain in a high impedance state.
GX5295:
Each channel has an independent load with the following capabilities:
● Channels’ Input constant source and sink currents up to 24 mA – DioSetupInputLoadCurrent function.
● Maintain high impedance over a wide voltage.
● Single clamping (commutating) voltage – DioSetupInputLoadCurrentVoltageClamps function.
● With a single commutating voltage, the source and sink currents have a single threshold voltage.
Channels input source and sink constant currents can be read back and set dynamically at any time even while the DIO is running mode.
The following example uses an array of channels list to enables the Input load state:
SHORT anChannelList[]={0, 2, 5, 7, 9, 13, 14, 27};
DioSetupInputLoadState (nHandle, DIO_CH_LIST_MODE_ARRAY_OF_CHANNELS, 8, anChannelList, 0, DIO_LOAD_CONNECTED, &nStatus);
The following example enables all the board’s channels Input load states:
DioSetupInputLoadState (nHandle, DIO_CH_LIST_MODE_ALL_BOARD_CHANNELS, 0, NULL , 0, DIO_LOAD_CONNECTED, &nStatus);
The following example enables all the boards channels Input load states:
DioSetupInputLoadState (nHandle, DIO_CH_LIST_MODE_ALL_DOMAIN_CHANNELS, 0, NULL , 0, DIO_LOAD_CONNECTED, &nStatus);
The following example enables channels 5 to 10 Input load state:
DioSetupInputLoadState (nHandle, DIO_CH_LIST_MODE_RANGE_OF_CHANNELS, 5, NULL, 10, DIO_LOAD_CONNECTED, &nStatus);
DioSetupInputLoadCurrent, DioSetupInputLoadResistance, DioSetupInputThresholdVoltages , DioGetErrorString