The following functions exist in the compatibility driver. These functions return one of the following status codes:
* The GX2065 has a 2A fuse. Some measurements in this range may overflow and/or blow the fuse when switching from Signametrics cards to the GX2065.
VDC |
||
SMX204x |
SMX2060 |
GX2065 |
_300mV |
_240mV |
GXDMM_RANGE_1V |
_3V |
_2400mV |
GXDMM_RANGE_10V |
_30V |
_24V |
GXDMM_RANGE_100V |
_300V |
_240V |
GXDMM_RANGE_300V |
_330V* |
||
VAC |
||
SMX204x |
SMX2060 |
GX2065 |
_300mV |
_240mV |
GXDMM_RANGE_500mVrms |
_3V |
_2400mV |
GXDMM_RANGE_5Vrms |
_30V |
_24V |
GXDMM_RANGE_50Vrms |
_300V |
_240V |
GXDMM_RANGE_300Vrms |
_330V* |
||
IDC |
||
SMX204x |
SMX2060 |
GX2065 |
_3mA |
_240nA |
GXDMM_RANGE_20mA |
_2400nA |
||
_24uA |
||
_240uA |
||
_2400uA |
||
_30mA |
_24mA |
GXDMM_RANGE_100mA |
_300mA |
_240mA |
GXDMM_RANGE_1A |
_3A* |
_2400mA* |
GXDMM_RANGE_2A |
IAC |
||
SMX204x |
SMX2060 |
GX2065 |
_3mA |
_2400uAAC |
GXDMM_RANGE_10mArms |
_30mA |
_24mAAC |
GXDMM_RANGE_50mArms |
_300mA |
_240mAAC |
GXDMM_RANGE_500mArms |
_3A* |
_2400mAAC* |
GXDMM_RANGE_1Arms |
OHMS2W and OHMS4W |
||
SMX204x |
SMX2060 |
GX2065 |
_30 |
_24 |
GXDMM_RANGE_100Ohm |
_300 |
_240 |
GXDMM_RANGE_1KOhm |
_3K |
_2400 |
GXDMM_RANGE_10KOhm |
_30k |
_24k |
GXDMM_RANGE_100KOhm |
_300k |
_240k |
GXDMM_RANGE_1MOhm |
_3MEG |
_2400k |
GXDMM_RANGE_10MOhm |
_30MEG |
_24MEG |
GXDMM_RANGE_100MOhm |
_300MEG* |
_240MEG* |
|
DIODE |
||
SMX204x |
SMX2060 |
GX2065 |
_D100n |
_D100n |
No equivalent |
_D1u |
_D1u |
|
_D10u |
_D10u |
GXDMM_RANGE_10uA |
_D100u |
_D100u |
GXDMM_RANGE_100uA |
_D1m |
_D1m |
GXDMM_RANGE_1mA |
_D10m |
_D10m |
No equivalent |