The GX3702 provides the same functionality as the GX3701 except the I/O configuration (connectors J1 – J4) is compatible with National Instruments’ PXI 7811R and PXI 7813R modules’ I/O.
Connections to the GX3700 may be made with 68-pin VHDCI male plug connector. Shielded cables with matching connectors are available from MTS. The I/O connections for the GX3702 are detailed in the tables below.
Pin# |
Flex I/O signal |
Description |
Pin# |
Flex I/O signal |
Description |
1 |
GND |
Ground |
35 |
FlexIO_P40 |
Single Ended / Pos Diff |
2 |
GND |
Ground |
36 |
FlexIO_N32 |
Single Ended / Neg Diff |
3 |
GND |
Ground |
37 |
FlexIO_P32 |
Single Ended / Pos Diff |
4 |
GND |
Ground |
38 |
FlexIO_P30 |
Single Ended / Pos Diff |
5 |
GND |
Ground |
39 |
FlexIO_N30 |
Single Ended / Neg Diff |
6 |
GND |
Ground |
40 |
FlexIO_P28 |
Single Ended / Pos Diff |
7 |
GND |
Ground |
41 |
FlexIO_N28 |
Single Ended / Neg Diff |
8 |
GND |
Ground |
42 |
FlexIO_N26 |
Single Ended / Neg Diff |
9 |
GND |
Ground |
43 |
FlexIO_P26 |
Single Ended / Pos Diff |
10 |
GND |
Ground |
44 |
FlexIO_N24 |
Single Ended / Neg Diff |
11 |
GND |
Ground |
45 |
FlexIO_P24 |
Single Ended / Pos Diff |
12 |
GND |
Ground |
46 |
FlexIO_N22 |
Single Ended / Neg Diff |
13 |
GND |
Ground |
47 |
FlexIO_P22 |
Single Ended / Pos Diff |
14 |
GND |
Ground |
48 |
FlexIO_N20 |
Single Ended / Neg Diff |
15 |
GND |
Ground |
49 |
FlexIO_P20 |
Single Ended / Pos Diff |
16 |
GND |
Ground |
50 |
FlexIO_N18 |
Single Ended / Neg Diff |
17 |
GND |
Ground |
51 |
FlexIO_P18 |
Single Ended / Pos Diff |
18 |
GND |
Ground |
52 |
FlexIO_P16 |
Single Ended / Pos Diff |
19 |
GND |
Ground |
53 |
FlexIO_N16 |
Single Ended / Neg Diff |
20 |
GND |
Ground |
54 |
FlexIO_N14 |
Single Ended / Neg Diff |
21 |
GND |
Ground |
55 |
FlexIO_P14 |
Single Ended / Pos Diff |
22 |
GND |
Ground |
56 |
FlexIO_N12 |
Single Ended / Neg Diff |
23 |
GND |
Ground |
57 |
FlexIO_P12 |
Single Ended / Pos Diff |
24 |
GND |
Ground |
58 |
FlexIO_P10 |
Single Ended / Pos Diff |
25 |
GND |
Ground |
59 |
FlexIO_N10 |
Single Ended / Neg Diff |
26 |
GND |
Ground |
60 |
FlexIO_N8 |
Single Ended / Neg Diff |
27 |
+5V |
Backplane +5V |
61 |
FlexIO_P8 |
Single Ended / Pos Diff |
28 |
+5V |
Backplane +5V |
62 |
FlexIO_N6 |
Single Ended / Neg Diff |
29 |
FlexIO_P4 |
Single Ended / Pos Diff side |
63 |
FlexIO_P6 |
Single Ended / Pos Diff |
30 |
FlexIO_N2 |
Single Ended / Neg Diff |
64 |
FlexIO_N4 |
Single Ended / Neg Diff |
31 |
FlexIO_N34 |
Single Ended / Neg Diff |
65 |
FlexIO_P2 |
Single Ended / Pos Diff |
32 |
FlexIO_P36 |
Single Ended / Neg Diff |
66 |
FlexIO_P34 |
Single Ended / Pos Diff |
33 |
FlexIO_P38 |
Single Ended / Pos Diff side |
67 |
FlexIO_N36 |
Single Ended / Neg Diff |
34 |
FlexIO_P40 |
Single Ended / Pos Diff side |
68 |
FlexIO_N38 |
Single Ended / Neg Diff |
J1 Flex IO Bank A Pin Out
Legend:
● FlexIO_PXX (Single Ended / Pos Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file provided by Marvin Test Solution GxFpga setup, can be Single Ended or Differential Positive side as defined by the Firmware
● FlexIO_NXX (Single Ended / Neg Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file, can be Single Ended or Differential Negative side as defined by the Firmware
● +5V: From the Backplane going through a 2.4A self-resettable fuse.
● Diff Clock Input: Dedicated differential clock inputs. For user designs, this Flex I/O can be repurposed as an addition input/output line.
Cross reference between Flex I/O lines as they are defined in the TCL file and the J2 connector
Pin# |
Flex I/O signal |
Description |
Pin# |
Flex I/O signal |
Description |
1 |
GND |
Ground |
35 |
FlexIO_N39 |
Single Ended / Neg Diff |
2 |
GND |
Ground |
36 |
FlexIO_P39 |
Single Ended / Pos Diff side |
3 |
GND |
Ground |
37 |
FlexIO_N37 |
Single Ended / Neg Diff |
4 |
GND |
Ground |
38 |
FlexIO_P37 |
Single Ended / Pos Diff side |
5 |
GND |
Ground |
39 |
FlexIO_N35 |
Single Ended / Neg Diff |
6 |
GND |
Ground |
40 |
FlexIO_P35 |
Single Ended / Pos Diff side |
7 |
GND |
Ground |
41 |
FlexIO_N33 |
Single Ended / Neg Diff |
8 |
GND |
Ground |
42 |
FlexIO_P33 |
Single Ended / Pos Diff side |
9 |
GND |
Ground |
43 |
FlexIO_N1 |
Single Ended / Neg Diff |
10 |
GND |
Ground |
44 |
FlexIO_P1 |
Single Ended / Pos Diff side |
11 |
GND |
Ground |
45 |
FlexIO_P3 |
Single Ended / Pos Diff side |
12 |
GND |
Ground |
46 |
FlexIO_N3 |
Single Ended / Neg Diff |
13 |
GND |
Ground |
47 |
FlexIO_N5 |
Single Ended / Neg Diff |
14 |
GND |
Ground |
48 |
FlexIO_P5 |
Single Ended / Pos Diff side |
15 |
GND |
Ground |
49 |
FlexIO_P7 |
Single Ended / Pos Diff side |
16 |
GND |
Ground |
50 |
FlexIO_N7 |
Single Ended / Neg Diff |
17 |
GND |
Ground |
51 |
FlexIO_P9 |
Single Ended / Pos Diff side |
18 |
GND |
Ground |
52 |
FlexIO_N9 |
Single Ended / Neg Diff |
19 |
GND |
Ground |
53 |
FlexIO_P11 |
Single Ended / Pos Diff side |
20 |
GND |
Ground |
54 |
FlexIO_N11 |
Single Ended / Neg Diff |
21 |
GND |
Ground |
55 |
FlexIO_P13 |
Single Ended / Pos Diff side |
22 |
GND |
Ground |
56 |
FlexIO_N13 |
Single Ended / Neg Diff |
23 |
GND |
Ground |
57 |
FlexIO_N15 |
Single Ended / Neg Diff |
24 |
GND |
Ground |
58 |
FlexIO_P15 |
Single Ended / Pos Diff side |
25 |
GND |
Ground |
59 |
FlexIO_N17 |
Single Ended / Neg Diff |
26 |
GND |
Ground |
60 |
FlexIO_P17 |
Single Ended / Pos Diff side |
27 |
+5V |
Backplane +5V |
61 |
FlexIO_N19 |
Single Ended / Neg Diff |
28 |
+5V |
Backplane +5V |
62 |
FlexIO_P19 |
Single Ended / Pos Diff side |
29 |
FlexIO_P21 |
Single Ended / Pos Diff side |
63 |
FlexIO_N21 |
Single Ended / Neg Diff |
30 |
FlexIO_N23 |
Single Ended / Neg Diff |
64 |
FlexIO_P23 |
Single Ended / Pos Diff side |
31 |
FlexIO_N25 |
Single Ended / Neg Diff |
65 |
FlexIO_P25 |
Single Ended / Pos Diff side |
32 |
FlexIO_N27 |
Single Ended / Neg Diff |
66 |
FlexIO_P27 |
Single Ended / Pos Diff side |
33 |
FlexIO_P29 |
Single Ended / Pos Diff side |
67 |
FlexIO_N29 |
Single Ended / Neg Diff |
34 |
FlexIO_P31 |
Single Ended / Pos Diff side |
68 |
FlexIO_N31 |
Single Ended / Neg Diff |
J2 Flex IO Bank B Pin Out
Pin# |
Flex I/O signal |
Description |
Pin# |
Flex I/O signal |
Description |
1 |
GND |
Ground |
35 |
FlexIO128 |
Single Ended |
2 |
GND |
Ground |
36 |
FlexIO127 |
Single Ended |
3 |
GND |
Ground |
37 |
FlexIO126 |
Single Ended |
4 |
GND |
Ground |
38 |
FlexIO125 |
Single Ended |
5 |
GND |
Ground |
39 |
FlexIO124 |
Single Ended |
6 |
GND |
Ground |
40 |
FlexIO123 |
Single Ended |
7 |
GND |
Ground |
41 |
FlexIO122 |
Single Ended |
8 |
GND |
Ground |
42 |
FlexIO121 |
Single Ended |
9 |
GND |
Ground |
43 |
FlexIO120 |
Single Ended |
10 |
GND |
Ground |
44 |
FlexIO119 |
Single Ended |
11 |
GND |
Ground |
45 |
FlexIO118 |
Single Ended |
12 |
GND |
Ground |
46 |
FlexIO117 |
Single Ended |
13 |
GND |
Ground |
47 |
FlexIO116 |
Single Ended |
14 |
GND |
Ground |
48 |
FlexIO115 |
Single Ended |
15 |
GND |
Ground |
49 |
FlexIO114 |
Single Ended |
16 |
GND |
Ground |
50 |
FlexIO113 |
Single Ended |
17 |
GND |
Ground |
51 |
FlexIO112 |
Single Ended |
18 |
GND |
Ground |
52 |
FlexIO111 |
Single Ended |
19 |
GND |
Ground |
53 |
FlexIO110 |
Single Ended |
20 |
GND |
Ground |
54 |
FlexIO109 |
Single Ended |
21 |
GND |
Ground |
55 |
FlexIO108 |
Single Ended |
22 |
GND |
Ground |
56 |
FlexIO107 |
Single Ended |
23 |
GND |
Ground |
57 |
FlexIO106 |
Single Ended |
24 |
GND |
Ground |
58 |
FlexIO105 |
Single Ended |
25 |
GND |
Ground |
59 |
FlexIO104 |
Single Ended |
26 |
GND |
Ground |
60 |
FlexIO103 |
Single Ended |
27 |
+5V |
Backplane +5V |
61 |
FlexIO102 |
Single Ended |
28 |
+5V |
Backplane +5V |
62 |
FlexIO101 |
Single Ended |
29 |
FlexIO100 |
Single Ended |
63 |
FlexIO99 |
Single Ended |
30 |
FlexIO98 |
Single Ended |
64 |
FlexIO97 |
Single Ended |
31 |
FlexIO63 |
Single Ended |
65 |
FlexIO61 |
Single Ended |
32 |
FlexIO59 |
Single Ended |
66 |
FlexIO57 |
Single Ended |
33 |
FlexIO55 |
Single Ended |
67 |
FlexIO53 |
Single Ended |
34 |
FlexIO_N41 |
Single Ended / Neg Diff |
68 |
FlexIO_P41 |
Single Ended / Pos Diff |
J3 Flex IO Bank C Pin Out
Legend:
● FlexIO_PXX (Single Ended / Pos Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file provided by Marvin Test Solution GxFpga setup, can be Single Ended or Differential Positive side as defined by the Firmware
● FlexIO_NXX (Single Ended / Neg Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file, can be Single Ended or Differential Negative side as defined by the Firmware
● FlexIO_XX (Single Ended): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file, can only be Single Ended.
● +5V: From the Backplane going through a 2.4A self-resettable fuse.
Pin# |
Flex I/O signal |
Description |
Pin# |
Flex I/O signal |
Description |
1 |
GND |
Ground |
35 |
FlexIO_N42 |
Single Ended / Neg Diff |
2 |
GND |
Ground |
36 |
FlexIO_P42 |
Single Ended / Pos Diff |
3 |
GND |
Ground |
37 |
FlexIO54 |
Single Ended |
4 |
GND |
Ground |
38 |
FlexIO56 |
Single Ended |
5 |
GND |
Ground |
39 |
FlexIO58 |
Single Ended |
6 |
GND |
Ground |
40 |
FlexIO60 |
Single Ended |
7 |
GND |
Ground |
41 |
FlexIO62 |
Single Ended |
8 |
GND |
Ground |
42 |
FlexIO64 |
Single Ended |
9 |
GND |
Ground |
43 |
FlexIO96 |
Single Ended |
10 |
GND |
Ground |
44 |
FlexIO95 |
Single Ended |
11 |
GND |
Ground |
45 |
FlexIO94 |
Single Ended |
12 |
GND |
Ground |
46 |
FlexIO93 |
Single Ended |
13 |
GND |
Ground |
47 |
FlexIO92 |
Single Ended |
14 |
GND |
Ground |
48 |
FlexIO91 |
Single Ended |
15 |
GND |
Ground |
49 |
FlexIO90 |
Single Ended |
16 |
GND |
Ground |
50 |
FlexIO89 |
Single Ended |
17 |
GND |
Ground |
51 |
FlexIO88 |
Single Ended |
18 |
GND |
Ground |
52 |
FlexIO87 |
Single Ended |
19 |
GND |
Ground |
53 |
FlexIO86 |
Single Ended |
20 |
GND |
Ground |
54 |
FlexIO85 |
Single Ended |
21 |
GND |
Ground |
55 |
FlexIO84 |
Single Ended |
22 |
GND |
Ground |
56 |
FlexIO83 |
Single Ended |
23 |
GND |
Ground |
57 |
FlexIO82 |
Single Ended |
24 |
GND |
Ground |
58 |
FlexIO81 |
Single Ended |
25 |
GND |
Ground |
59 |
FlexIO80 |
Single Ended |
26 |
GND |
Ground |
60 |
FlexIO79 |
Single Ended |
27 |
+5V |
+5V from Backplane |
61 |
FlexIO78 |
Single Ended |
28 |
+5V |
+5V from Backplane |
62 |
FlexIO77 |
Single Ended |
29 |
FlexIO76 |
Single Ended |
63 |
FlexIO75 |
Single Ended |
30 |
FlexIO74 |
Single Ended |
64 |
FlexIO73 |
Single Ended |
31 |
FlexIO72 |
Single Ended |
65 |
FlexIO71 |
Single Ended |
32 |
FlexIO70 |
Single Ended |
66 |
FlexIO69 |
Single Ended |
33 |
FlexIO68 |
Single Ended |
67 |
FlexIO67 |
Single Ended |
34 |
FlexIO66 |
Single Ended |
68 |
FlexIO65 |
Single Ended |
J4 Flex IO Bank D Pin Out
Legend:
● FlexIO_PXX (Single Ended / Pos Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file provided by Marvin Test Solution GxFpga setup, can be Single Ended or Differential Positive side as defined by the Firmware
● FlexIO_NXX (Single Ended / Neg Diff): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file, can be Single Ended or Differential Negative side as defined by the Firmware
● FlexIO_XX (Single Ended): Altera Stratix III FPGA Flex I/O signal name as defined in the TCL (Tool Command Language) file, can only be Single Ended.
● +5V: From the Backplane going through a 2.4A self-resettable fuse.