Error Codes

Error Value
Description
Warnings/Info
100
Measurement is out of range.
110
High Power chassis error: There is no secondary power supply controller installed to control VCC2.
General Resource Errors
0
No error has occurred.
-1
Unable to open the HW driver. Check if HW is properly installed.
-2
Board does not exist in this slot/base address.
-3
Different board exist in the specified PCI/PXI slot/base address.
-4
PCI/PXI slot not configured properly. You may configure using the PCI/PXI Explorer from the Windows Control Panel.
-5
Unable to register the PCI/PXI device.
-6
Unable to allocate system resource for the device.
-7
Unable to allocate memory.
-8
Unable to create panel.
-9
Unable to create Windows timer.
-10
Bad or Wrong board EEPROM.
-11
Not in calibration mode.
-12
Board not calibrated.
-13
Function is not supported by this board type.
General Parameter Error
-20
Invalid or unknown error number.
-21
Invalid parameter.
-22
Illegal slot number.
-23
Illegal board handle.
-24
Illegal string length.
-25
Invalid mode.
Visa Errors
-30
Unable to Load VISA32/64.DLL, make sure VISA library is installed.
-31
Unable to open default VISA resource manager, make sure VISA is properly installed.
-32
Unable to open the specified VISA resource.
-33
VISA viGetAttribute error.
-34
VISA viInXX error.
-35
VISA ViMapAddress error.
Misc Errors
-38
Unable to lock a board resource, resource is used by another process or thread.
Driver Specific Error Codes
-100
Error opening file.
-101
Error closing file.
-102
Error writing file.
-103
Error reading file.
-104
Invalid T964 session pointer.
-105
Missing configuration file header.
-106
Unable to allocate memory.
-107
Error requesting memory, memory Busy. Sequencer is active.
-108
Error requesting memory, memory not granted.
-109
Invalid Frequency Synthesizer Register Setting.
-110
Frequency Synthesizer Acknowledge Error.
-111
Invalid pattern set number specified.
-112
Sequence Step Not Initialized.
-113
Maximum number of patterns exceeded.
-114
Specified offset must be multiple of four.
-115
Invalid pattern data code in array.
-116
Invalid pin in array.
-117
Idle sequence not defined.
-118
Operation not valid while sequence active.
-119
Invalid channel list.
-120
Invalid current load source/sink voltage (source <= sink).
-121
Unable to perform transfer, I2C Bus Busy.
-122
I2C Acknowledge not received.
-123
Installed front end board does not support this function.
-124
Empty slot in DRS chain not allowed.
-125
Digital board sequencer revision not supported with this driver revision.
-126
Invalid function/setting for current timing mode.
-127
Invalid setting for current clock source.
-128
Cannot disable cache mode, cache not empty.
-129
Min/max voltage swing exceeded.
-130
Channel bus timeout.
-131
I2C bus timeout.
-132
Frequency Synthesizer bus timeout.
-133
Input delay DCM, sequencer A not locked.
-134
Input delay DCM, sequencer B not locked.
-135
Installed digital control board does not support this function.
-136
Waveform transition data error.
-137
Invalid Domain configuration specified.
-138
Channel deskew calibration assert out of range at last board in the domain.
-139
Channel deskew calibration delay out of range.
-140
500MHz Clock Not Ready.
-141
Input delay control, sequencer A not locked.
-142
Input delay control, sequencer B not locked.
-143
Timing signal calibration timeout.
-146
Invalid Parameter.
-147
Board does not exist in this slot/base address.
-148
Saturn timeout.
-149
This device is not supported by the function called.
-150
No Channel deskew calibration delay values were set.
-151
Not matching Loop command in XML file.
-152
Invalid board handle.
-153
GTDIO6x domain configuration file is empty.
-154
Invalid slave board number.
-155
No slave board found.
-156
Invalid InterConnect Mode.
-157
Invalid voltage supply rails.
-158
Domain is not contiguous, correct domain settings.
-159
Could not access Xilinx FPGA Firmware file.
-160
Xilinx FPGA Firmware Programming Error.
-161
Memory Test Error.
-162
Slew Rate Calibration Error.
-163
Invalid Slew Rate Setting.
-164
Emerson Power Supply I2C Communication Timed Out.
-165
Emerson Power Supply DC Fault on Supply Enable.
-166
Invalid Skew Delay, Out of Range.
-167
Domain does not support power supply.
-168
Local Bus Delay Exceeded, Channel Deskew Failed.
-169
Power Supply State in unknown condition.
-170
Invalid subsequent sequence step settings, the minimum execution time of any subsequent sequence step needs to be at least 400nSec. Step execution time is equal to: Period In nSec * Step's Vector Count * Step's Clocks Per Vector.
-171
Domain does not support high-power chassis supply.
-172
High power chassis I2C Communication Timed Out.
-173
High power chassis supply DC Fault on Supply Enable.
-174
Power Supply VCC Setting is out of range, try a voltage that is less than or equal to 28 Volts and greater than or equal to 10 Volts.
-175
Power Supply VDD Setting is out of range, try to call DioPowerSupplyResetFault API.
-176
Power Supply VEE Setting has been exceeded, try a voltage that is less than or equal to 18 Volts and greater than or equal to 3 Volts.
-177
Power Supply Maximum Swing Voltage exceeded, try a voltage swing that is less than or equal to 32 Volts.
-178
Power Supply State in unknown condition.
-179
High power chassis supply AC Fault on Supply Enable.
-180
High Power chassis fault: VCC voltage rails generated a fault.
-181
High Power chassis fault: VEE voltage rails generated a fault.
-182
High Power chassis fault: Power Supply Maximum Swing Voltage exceeded.
-183
High Power chassis error: Power Supply did not acknowledge all bytes in transmission.
-184
Unable to execute settings since the sequencer is running.
-185
Unable to execute settings since the sequencer is running the Idle Step.
-186
Error: Timeout when trying to read voltage from the ADC.
-187
Error: Timeout when trying to ARM the domain.
-188
Error: Timeout when trying to form the on board EEPROM.
-189
Error: Channel mode is out of range.
-190
Error: not all boards in the domain ran, use GtDio6xSequencerGetDomainRunStatusAPI to find out which boards didn't run.
-200
More pattern data than pin list data.
-201
ADC data not stable.
-202
Channel list query data mixed.
-203
More data available.
-204
Front end module data not loaded due to incompatible type.
-205
MAX6697 Diode Fault.
-206
Offset/Gain DAC values out of range.
-207
Driver overhead exceeded.
-208
Comparator overhead exceeded.
-209
Comparator and Driver overhead exceeded.
-210
Load overhead exceeded.
-211
Load and Driver overhead exceeded.
-212
Load and Comparator overhead exceeded.
-213
Load, Comparator and Driver overhead exceeded.
-214
Unknown Front End Module.
-215
Installed front end board does not support this query.
-216
DRM Auto calibration out of range.
-220
Unable to unmap DMA memory.
-221
Unable to map DMA memory.
-222
Unable to free DMA memory.
-223
Unable to allocate DMA memory.
-224
Error: not all expected data was transferred.
-225
DMA enables failed.
-226
DMA Transfer Progress timeout.
-230
Invalid Signal Active Mode.
-231
The write/read command tries to access memory past its configured depth.
-232
Illegal timeout or not enough time to complete Pin Electronics setup (wait for ready).
-233
EEPROM timeout.
-234
Unable to communicate with all Pin Electronics ICs.
-240
Timeout: Unable to reconfigure the PLL.
-241
Timeout: Unable to reset the PLL.
-242
Timeout: Unable to write values to the PLL.
-243
Timeout: Unable to program PLL post values.
-245
Timeout: Unable to lock the PLL.
-246
Timeout: Unable to reconfigure PLL phase.
-247
Invalid PLL Edge settings.
-300
Array Size Error.
-302
Record Mode Error.
-303
Pulse Width Error.
-304
Master Clock Source Error.
-305
System Clock Source Error.
-306
System Clock Mode Error.
-307
System Clock Offset Error.
-308
Timing Mode Error.
-309
Input Disable Error.
-310
Channel Over current Error.
-311
Global Over current Error.
-312
Over current Window Error.
-313
Record Error Mode Error.
-314
Record Response Mode: value is out of range.
-315
Record Type Error: value is out of range.
-316
Record Offset Error: value is out of range.
-317
Error Count Basis Error: value is out of range.
-318
Error Address Basis Error.
-319
Pass Fail Basis Error.
-320
Pass Valid Mode Error.
-321
Probe Data Mode Error.
-322
Probe CRC Mode Error.
-323
Probe Offset Error.
-324
Probe LED Enable Error.
-325
Reference Source Error: value is out of range.
-326
Reference Frequency Error: value is out of range.
-327
Frequency Error: value is out of range.
-328
Timer State Error.
-329
Timer Value Error.
-330
Timer Error.
-331
Trigger Error.
-332
Trigger Source Error.
-333
Inversion Error.
-334
Trigger Mode Error.
-335
Trigger Reset Error.
-336
Phase Selection Error.
-337
Data Format Error.
-338
Window Selection Error.
-339
Capture Mode Error.
-340
Channel State Error.
-341
Voltage Output High Error.
-342
Voltage Output Low Error.
-343
Output Impedance Error.
-344
Voltage Input High Error.
-345
Voltage Input Low Error.
-346
Timing Set Error.
-347
Timing Set Group Error.
-348
Timing Phase Assert Error.
-349
Timing Phase Return Error.
-350
Timing Window Open Error.
-351
Timing Window Close Error.
-352
Channel Test Error.
-353
Channel Test Expect Error.
-354
Channel Test Mask Error.
-355
Condition Pipeline Mask Error.
-356
Vector Address Bit Error.
-357
Signal Source Error: value is out of range.
-358
Vector Index Error: value is out of range.
-359
Jump Step Error: value is out of range.
-360
Jump Strobe Error: value is out of range.
-361
Loop Counter Error: value is out of range.
-362
Loop Mode Error: value is out of range.
-363
First Step Error: value is out of range.
-364
Number Of Steps Error: value is out of range.
-365
Sequence Step Error: value is out of range.
-366
Number Of Patterns: value is out of range.
-367
Memory Offset Error: value is out of range.
-368
Clock Period Error: value is out of range.
-369
Clocks Per Pattern Error: value is out of range.
-370
Jump Type Error: value is out of range.
-371
Jump Condition Error: value is out of range.
-372
Vector Jump Error: value is out of range.
-373
Loop Count Error: value is out of range.
-374
Resume Modifier Error: value is out of range.
-375
Last Step Error: value is out of range.
-376
GoSub Return Flag Error.
-377
Timeout Continue Error: value is out of range.
-378
Sequence Flag 1 Error.
-379
Sequence Flag 2 Error.
-380
Record Mode Error: value is out of range.
-381
Phase 1 Trigger Error: value is out of range.
-382
Phase 2 Trigger Error: value is out of range.
-383
Phase 3 Trigger Error: value is out of range.
-384
Phase 4 Trigger Error: value is out of range.
-385
Waveform 1 Enable Error: value is out of range.
-386
Waveform 2 Enable Error: value is out of range.
-387
Waveform 3 Enable Error: value is out of range.
-388
Waveform 4 Enable Error: value is out of range.
-389
Waveform Table Error: value is out of range.
-390
Pattern Data Size Error: value is out of range.
-391
Pattern Data Error: value is out of range.
-392
Pattern Number Error: value is out of range.
-393
Enable Error.
-394
Offset Error: value is out of range.
-395
Number Of Sets Error: value is out of range.
-396
Waveform Table Size: value is out of range.
-397
Power State Error.
-398
Driver State Error.
-399
Unable to stop the Sequencer: value is out of range.
-400
Unable to Halt the Sequencer.
-401
Finish Mode Error: value is out of range.
-402
Burst Count Error: value is out of range.
-403
Waveform Number Error: value is out of range.
-404
Beginning Level Error: value is out of range.
-405
Array Size Error: value is out of range.
-406
Transition Data Error.
-407
Error Address Error.
-408
Error Count Error: value is out of range.
-409
Invalid channel number.
-410
CRC Data Error.
-411
Starting Error Error.
-412
Number of Real Time Compare Errors exceeds 1024.
-413
Pattern Address Error.
-414
Word Index Error.
-415
Starting Address Error.
-416
Record Data Error.
-417
Probe Data Error.
-418
Good 0 CRC Error.
-419
Good 1 CRC Error.
-420
Time Error.
-421
Sync Output Error.
-422
Sync Event Error.
-423
Sync Step Error.
-424
Sync Offset Error.
-425
Sync Length Error.
-426
PXI Trigger Error.
-427
Signal Error.
-428
Signal Type Error.
-429
Local Trigger Error.
-430
Pin Not Found In Domain Error.
-431
Power Supply VCC Setting is out of range, try a voltage that is less than or equal to 28 Volts and greater than or equal to 10 Volts.
-432
Power Supply VEE Setting has been exceeded, try a voltage that is less than or equal to 18 Volts and greater than or equal to 3 Volts.
-433
Power Supply Maximum Swing Voltage exceeded, try a voltage swing that is less than or equal to 32 Volts.
-434
Saturn Pin Electronics IC not responding.
-435
Invalid file saves number of steps.
-437
Channel name already exists, choose unique name.
-438
Sequence Step name already exists, choose unique name.
-439
Sequence Step with that name does not exist.
-440
Invalid Vector Memory Fill type selected.
-441
Invalid path, could not save configuration.
-442
Invalid path, could not load configuration.
-443
Invalid channels found in the channel list.
-444
Invalid step number.
-445
Too many file handles open, close a file.
-446
Invalid file mode.
-447
Invalid File Handle, Handle is not associated with a file.
-448
File (Path) cannot be found.
-449
Handle is not associated with a Master board (Domain).
-450
Cannot set file setting because file was opened in read-only mode.
-451
Choose a file step count of 1-1024.
-452
Choose a file channel count of 1-1024
-453
Vector Starting Address and/or Vector size is out of range (invalid).
-454
Calibration not supported.
-455
Invalid PMU Current Range.
-456
Invalid Channel VCOM High Voltage.
-467
Invalid Channel VCOM Low Voltage.
-469
Invalid Channel Source High Voltage.
-470
Invalid Channel Source Low Voltage.
-471
Invalid Channel Sense High Voltage.
-472
Invalid Channel Sense Low Voltage.
-473
Invalid Channel Output Current Limit.
-474
Invalid Channel Input Current Load.
-475
Invalid Channel PMU Force Voltage.
-476
Invalid Channel termination Voltage.
-477
Invalid PMU comparator Low Voltage.
-478
Invalid PMU comparator High Voltage.
-479
Invalid PMU comparator Voltage.
-480
Invalid PMU forced voltage over current.
-481
Illegal timeout or not enough time to finish the Serial ADC measurement.
-482
Static Channel Readback error.
-483
Channel Deskew value out of range.
-484
Power supply rails not detected.
-500
Pin not found in domain.
-501
Invalid Formatting option in XML file.
-502
Not Enough Mapped Pins, check PinRemapping Array or Size.
-503
Not Enough physical pins present in domain, check domain settings.
-506
Record Expected Data Offset Error: value is out of range.
File errors
-600
DIOX File type: error file open.
-601
DIOX File type: unable to create file.
-602
DIOX File type: unable to open group.
-603
DIOX File type: error reading data storage.
-604
DIOX File type: error writing data storage.
-605
DIOX File type: error closing data set.
-606
DIOX File type: error closing data space.
-607
DIOX File type: error release data type.
-608
DIOX File type: error resize data.
-609
DIOX File type: error add board.
-610
DIOX File type: error file board.
-611
DIOX File type: error invalid board type.
-612
DIOX File type: error file board create.
-613
DIOX File type: error file not HDF type.
-614
DIOX File type: error invalid steps per block.
-615
DIOX File type: error invalid open mode.
-616
DIOX File type: error invalid storage data type.
-617
DIOX File type: error creating data set.
-618
DIOX File type: error open data set.
-619
DIOX File type: error attribute does not exist.
Memory Test errors
-650
Error Memory Test: Vector Memory channels 0-7.
-651
Error Memory Test: Vector Memory channels 8-15.
-652
Error Memory Test: Vector Memory channels 16-23.
-653
Error Memory Test: Vector Memory channels 24-31.
-654
Error Memory Test: Record Memory.
-655
Error Memory Test: Probe Memory.
-656
Error Memory Test: Steps Memory (4K steps memory data).
-658
Error Memory Test: Persistence Memory.
-659
Error Memory Test: Waveform Memory.
-660
Error Memory Test: Vector index Memory.
-661
Error Memory Test: Real Time compare error Memory.
-662
Error Memory Test: Timing Set Index Memory.
-663
Error Memory Test: Cross talk between memory banks.
-670
Error I/O Test: Monitor Fail: unable to Detect VCC voltage.
-671
Error I/O Test: Monitor Fail, unable to Detect VEE voltage.
-672
Error I/O Test: Monitor Fail, unable to Detect VDD voltage.
-673
Error I/O Test: Failed Voltage Drive High Test on channel.
-674
Error I/O Test: Failed Voltage Drive Low Test on channel.
Timing Set errors
-700
Error Timing Set Phase Value is out of range.
-701
Error Timing Set Window Value is out of range.
-702
Error Timing Set Edge Value is out of range.
-703
Error Timing Set Edge number is out of range.
-704
Error Timing Set Phase number is out of range.
-705
Error Timing Set Window number is out of range.
-706
Error Timing Set Memory Index number is out of range.
-707
Error Timing Set Memory Index subset number is out of range.
Compatibility errors
-800
Error Need a Firmware Upgrade in order to complete the operation.