Returns the specified group external update enable state.
GX1642, GX1648
GxAoGetGroupExternalUpdate (nHandle, nGroup, pbEnabled, pnStatus)
Name |
Type |
Description |
nHandle |
SHORT |
Handle to a GX6xx board |
nGroup |
SHORT |
Group number:0. GXAO_GROUPA1. GXAO_GROUPB2. GXAO_GROUPC3. GXAO_GROUPD |
pbEnabled |
PBOOL |
Return TRUE if the group external update is enabled and FALSE if disabled. |
pnStatus |
PSHORT |
Returned status: 0 on success, negative number on failure. |
When enabled a low on the group’s external update pin will continuously update the group voltage causing its DACs to be loaded from the channel register as set by the GxAoSetChannelVoltage.
The following example returns group A external update enable state:
SHORT nStatus
BOOL bEnabled;
GxAoGetGroupExternalUpdate (nHandle, GXAO_GROUPA, &bEnabled, &nStatus);
GxAoSetGroupExternalUpdate, GxAoSetChannelVoltage, GxAoSetGroupVoltageRange, GxAoGetGroupVoltageRange, GxAoGetErrorString