Gx5733ModuleSetOutputMode

Applies To

GX5702, GX5704

Purpose

Sets the Module’s Output mode.

Syntax

Gx5733ModuleSetOutputMode (nHandle, nPort, nMode, pnStatus)

Parameters

Name
Type
Description
nHandle
SHORT
Handle to a GX5733 board.
nPort
SHORT
Module port 0 (GX5733_PORT0) only.
nMode
SHORT
Module’s Output mode as follow:
0. GX5733_MODULE_OUTPUT_DISABLE: All the Module’s 32 channels are in Tri-State mode.
1. GX5733_MODULE_OUTPUT_ENABLE: All the Module’s 32 channels are enabled to output data.
pnStatus
PSHORT
Returned status: 0 on success, negative number on failure.

Comments

Outputs are set to Tri-State when in disabled.

Example

The following example enables the module port 0 output mode:

 

SHORT nStatus;

Gx5733ModuleGetOutputMode (nHandle, GX5733_PORT0, GX5733_MODULE_OUTPUT_ENABLE, &nStatus);

 

See Also

Gx5733ModuleGetOutputMode, Gx5733ModuleSetStrobeSource