The following table gives the specifications for the two versions of GX6264 switching instruments. The commercial version uses plastic molded DIP (dual in-line packaged) reed relays and is suitable for most testing applications. The industrial version (Hi-REL) is more reliable. Offering higher voltage and current ratings.
Relay Format |
1A1B |
|
Channel Resistance |
0.3 W0.1 W |
MaximumTypical |
Relay Contact Resistance |
0.1 W0.03 W |
MaximumInitial |
Contact Life Rating |
Mech. 10 MillionElect. 100,000 |
Rated Load |
Switching Voltage |
240 VAC 30 VDC |
Maximum |
Switching Current |
7.0 A |
Maximum |
Contact Carry Current |
7.0 A |
Maximum |
Operate Time |
10mS @ nominal voltage |
Excluding bounce |
Release Time |
5mS @ nominal voltage |
Excluding bounce |
Driver Channels |
3 Open Collector outputs |
Current |
500 mA sink per driver |
3.3V Power (mA): |
160 mA |
5V Typical Power (A): |
70mA per channel |
5V Maximum Power (A): |
1.75A max |
Operating Temperature: |
-40 to +70°C |
Storage Temperature: |
-40 to+100°C |
Vibration |
9g at 10-55Hz |
Shock ½ Sine |
100G for 6mS |
Size |
3U PXI |
Weight |
250g |