Specifications

The following table outlines the specifications of the GX6188:

GX6188 Switching Specifications
Configuration
(4) 26 x 8 matrices and (1) 8 x 8 matrix
Inputs
8 via external resource or global bus connections
Internal Global Bus Configuration
8-wire, accessible via 104x8 & 8x8 matrices and external connector
Global Bus Resources
2.2 KΩ grounded bleed resistor
BIT voltage source (100KΩ pullup to 3.3V)
UUT Inputs / Outputs
104
Relay Specifications
Max AC pk or DC voltage: 170 V
Max DC or AC pk carry current: 1A
Max DC or AC pk switching current: 0.5A
Max. contact rating:: 10 W
Signal Bandwidth
> 10 MHz, Input to Output (resource input to switch card output)
General Purpose I/O
Inputs/ Outputs
14, static read/write digital I/O signals
Logic Levels
LVTTL compatible
Functions
Cable ID, open relays via external input, generate interrupt via external input
I/O Connections
Output / UUT Channels
(2) 62 pin, D-sub, female connectors
Input / Resource
15 pin, D-sub, female connector
Global Bus
9 pin, D-sub, female connector
Environmental, Physical and Compliance
Operating
0 °C to +50 °C
Storage
-20 °C to +60 °C
Relative Humidity (operating)
5% to 80% RH, non-condensing
Relative Humidity (non-operating)
5% to 95% RH, non-condensing
Altitude (operating)
Up to 2000 M
Form Factor
6U, single slot
Weight
2.2 lbs.
CE Compliance
EN61010-1 (pending)
EN61326 (pending)