The following table outlines the specifications of the GX6256/GX6192/GX6864/GX6032/GX6009 switching cards:
Switching Specifications |
|
GX6032 Switch Card |
Configuration:
32 x16 |
GX6256 LF Switch Card |
Configuration:
16 x16 matrix with 2 to 1 selector, (16) 2:16 multiplexers |
GX6192 HF Switch Card |
Configuration:
16 x 16 matrix with (16) 1:12 multiplexers |
GX6864 VF Switch Card |
Configuration: 16 x 8 matrixInputs: 8 external analog inputs or 16 internal analog busOutputs: 64 |
Relay Specifications |
Max AC
pk or DC voltage 170 V |
Signal Bandwidth |
|
Input to Output (input switch card to LF switch card output) |
> 20 MHz |
HF Switch Card (external input to output) |
> 100 MHz |
I/O Connections |
|
GX6032 Switch Card |
32 coaxial connections (Positronics BD8W8F85R70T0/AA) |
GX6256 Switch Card |
Receiver:
Dual 200 pin connector |
GX6192 Switch Card |
Receiver:
Dual 200 pin connector |
GX6864 Switch Card |
Receiver: 2 - 32 pin coaxial connectors (Positronics BD8W8F85R70T0/AA)External: I/O: 8 coaxial connections (Positronics BD8W8F85R70T0/AA) |
The following table outlines the specifications of the GX7016 Chassis:
Chassis Specifications |
|
Input AC Power |
90 to 264 VAC, 12 A max (PFC) |
Total Available DC Power |
755 W |
+5 V |
60 A (max) |
Power Supply Monitoring |
Monitored
voltages: 3.3, 5, +12, -12, VIO value |
Temperature Monitoring |
Per slot monitoring, 1 reading/sec/slot
|
PXI Triggers |
Slots: 2 – 20
|
PXI Clock |
Integrated 10 MHz PXI clock with auto-detect function. Presence of an external 10 MHz PXI clock will disable the internal clock. PXI clock is distributed to all peripheral slots.10 MHz PXI clock accuracy: ±100 ppmExternal input: Rear panel (TTL compatible) or via timing slotOutput: Rear panel, (TTL compatible) |
Slots |
20 PXI or cPCI Slots (19 instruments max) |
Weight (core system) |
61 lbs |
Overall Dimensions |
10U (17.5") H x 19" W x 24" D |
Cooling |
Four 79 CFM fans for system cooling. Integrated temperature monitoring via an on-board microcontroller with audible and software notification when preset temperature limits are exceeded. Fan speed control and monitoring is automatic and can be controlled / monitored via the GxChassis software. |
The following table outlines the environmental specifications of the switching subsystem:
Environmental Specifications |
|
Operating |
0 °C to +50 °C |
Storage |
-20 °C to +60 °C |
Relative Humidity (operating) |
5% to 80% RH,non-condensing |
Relative Humidity (non-operating) |
5% to 95% RH,non-condensing |
Altitude (operating) |
Up to 2000 M |
CE Compliance |
EN61010-1
(pending) |