Returns all specified Module Strobe to PXI Trigger lines connection mode.
Gx5733ModuleGetPxiTriggerBus (nHandle, nPort, pnPxiTrigBus, pnStatus)
Name |
Type |
Description |
nHandle |
SHORT |
Handle to a GX5733 board. |
nPort |
SHORT |
Module port 0 (GX5733_PORT0) only. |
pnPxiTrigBus |
PSHORT |
Returns the specified Module’s eight output Strobe lines connections to the PXI Trigger Bus lines. The Strobe lines connections are 8 bits integer where each bit represents a PXI Trigger line. Bit 0 for line 0 and bit 7 for line 7. A high (‘1’) means the corresponding PXI Trigger line is connected; low (‘0’) means the corresponding PXI Trigger line is disconnected. |
pnStatus |
PSHORT |
Returned status: 0 on success, negative number on failure. |
Connections to the PXI Trigger Bus lines from the Module eight output Strobe lines can be done ion parallel, i.e. from any of currently installed Modules.
The following example returns all eight Strobe to PXI Trigger Bus lines to 0x5:
SHORT nPxiTrigBus, nStatus;
Gx5733ModuleGetPxiTriggerBus (nHandle, &nPxiTrigBus, &nStatus);
Gx5733ModuleSetPxiTriggerBus, Gx5733ModuleSetPxiTriggerLine, Gx5733GetStrobeToPxiTriggerBusState, Gx5733SetStrobeToPxiTriggerLineState