Gx5733ModuleGetPxiTriggerLine (nHandle, nPort, nPxiTrigLine, pnMode, pnStatus)
Name |
Type |
Description |
nHandle |
SHORT |
Handle to a GX5733 board. |
nPort |
SHORT |
Module port 0 (GX5733_PORT0) only. |
nPxiTrigLine |
SHORT |
PXI Trigger Line numbers are:0. GX5733_PXI_TRIGGER_LINE0: Line 01. GX5733_PXI_TRIGGER_LINE1: Line 12. GX5733_PXI_TRIGGER_LINE2: Line 23. GX5733_PXI_TRIGGER_LINE3: Line 34. GX5733_PXI_TRIGGER_LINE4: Line 45. GX5733_PXI_TRIGGER_LINE5: Line 56. GX5733_PXI_TRIGGER_LINE6: Line 67. GX5733_PXI_TRIGGER_LINE7: Line 7 |
pnMode |
PSHORT |
PXI trigger line mode are:0. GX5733_PXI_TRIGGER_LINE_DISCONNECTED: PXI trigger line is disconnected.1. GX5733_PXI_TRIGGER_LINE_CONNECTED: PXI trigger line is Connected |
pnStatus |
PSHORT |
Returned status: 0 on success, negative number on failure. |
Use the Gx5733ModuleSetPxiTriggerBus function to set all PXI-Trigger lines at once.
The following example returns PXI Trigger line 1 connection mode:
SHORT nMode, nStatus;
Gx5733ModuleGetPxiTriggerLine (nHandle, GX5733_PXI_TRIGGER_LINE1, &nMode, &nStatus);
Gx5733ModuleSetPxiTriggerBus, Gx5733ModuleSetPxiTriggerLine, Gx5733GetStrobeToPxiTriggerBusState, Gx5733SetStrobeToPxiTriggerLineState