GxSmuTrigGetAnyTriggerToConnector

Applies To

GX3116e

Purpose

Returns the trigger to the front connector from any selected trigger state.

Syntax

GxSmuTrigGetAnyTriggerToConnector (nHandle, pnState, pnStatus)

Parameters

Name
Type
Description
nHandle
SHORT
Handle to a GX3116e board.
pnState
PSHORT
Returns the state specified group’s external trigger as follows:
0.      GXSMU_TRIGGER_DISABLE: specified group’s external trigger is disabled
1.    GXSMU_TRIGGER_ENABLE: specified group’s external trigger is enabled
pnStatus
PSHORT
Returned status: 0 on success, negative number on failure.

Comments

The function returns the trigger to the front connector from any selected trigger state. If enabled and a trigger was issue, the Trigger output is active high and its nominal duration is 1ms.

Example

The following example enables the trigger to the front connector, and returns the settings:

 

SHORT nState, nStatus;

 

GxSmuTrigSetAnyTriggerToConnectornHandle, GXSMU_TRIGGER_ENABLE, &nStatus);

GxSmuTrigGetAnyTriggerToConnectornHandle, &nState, &nStatus);

 

See Also

GxSmuTriggerGroup, GxSmuTrigGetTriggerStatus, GxSmuTrigGetTriggerToPxiBusLine, GxSmuTrigSetAnyTriggerToAllGroups,  GxSmuTrigSetAnyTriggerToConnector, GxSmuTrigSetExternalTriggerToGroup, GxSmuTrigSetPxiTriggerBusLineToGroup, GxSmuTrigSetStarTriggerToGroup, GxSmuTrigSetTriggerToPxiBusLine, GxSmuGetErrorString