Description
The GX2482 series are a high performance, dual differential channel, 16-bit digitizer offering high dynamic range and excellent SFDR. The module’s differential inputs, coupled with its low distortion makes it an ideal instrument for analyzing high performance or low level analog signals. Each channel offers 3 selectable low pass filters, a 16 bit, 180 MS/s ADC, and 64 M words of memory for each channel. A PLL clock generator is combined with dedicated clock dividers for each digitizer channel, providing independent clocking and flexibility for each channel. The sample rate can be programmed from 1 MHz to 180 MHz. The module is available as a PXI hybrid slot compatible (GX2482) or PXI express compatible (GX2482e) instrument.
Features
The GX2482 provides two, differential inputs offering the ability to make low level measurements in the presence of common mode or noisy signals. The inputs can also be configured for single-ended operation. The input impedance is selectable for 1M ohm or 50 ohms and can be AC or DC coupled. Each channel can also add an offset to the input signal, providing the ability to maximize the A to D's dynamic range.
Both channels offer two, 3-pole, low pass, input filters providing the ability to band limit signal noise and minimize aliasing effects. The filters can also be bypassed to take advantage of the input amplifier's full bandwidth.
Clocking of the digitizer's two channels is provided by a PLL which uses a 10 MHz reference clock. The PLL can use the on-board, 10 MHz reference, the PXI 10 MHz clock, or an external clock input. Two independent, programmable dividers are driven by the PLL's output and provide independent sampling frequencies to the two digitizer channels. Digitizer triggering can be initiated via a PXI triggers, an external signal, a level on an input signal, or a software trigger.
Programming and Software
The board is supplied with a 32/64-bit DLL driver. Various interface files provide access to the DLL from programming tools and languages such as ATEasy, LabVIEW, LabWindows/CVI, C/C++, and more. The available virtual panel can be used to interactively adjust and control the instrument from a window that displays the instrument's current settings and measurements.
A PDF User's Guide provides documentation that includes instructions for installing, using and programming the board.
Applications
- Aerospace
- Defense
- Automotive testing
- High performance baseband testing
- Medical device and module test
- ATE systems
GX2482 Series Specifications
Hardware |
---|
Input Channels | (2) Differential analog (Ch 1+,Ch 1-,Ch 2+,Ch 2-) (1) External clock (1) External trigger |
Input Connectors | SMB |
A/D Converter |
---|
Resolution | 16 bits |
Sample Rate | 1 MS/s to 180 MS/s |
Memory | 64M samples per channel |
Clocking |
---|
Clock Divider | Programmable (one per channel) Range: 1 to 256 |
Clock Source | Programmable Dividers Internal PLL (2 kHz to 945 MHz) or External Clock (0 to 945 MHz) |
PLL Clock Reference | Internal 10 MHz, PXI 10 MHz, External Clock |
Analog Input Channels |
---|
Input Configuration | Differential or single-ended |
Input Range | 50 Ohm Impedance 0.256, 0.384, 0.512, 0.768, 1.024, 1.536, 2.048, 3.072 Vp |
Input Range | 1M Ohm Impedance 0.256, 0.384, 0.512, 0.768, 1.024, 1.536, 2.048, 3.072, 5.12, 7.86, 10.24, 15.36 Vp |
DC Offset | ± input range, 16 bit resolution |
Input Impedance | Selectable 50 Ohm, 1M Ohm |
Coupling | AC or DC |
Accuracy | ±(250uV + 0.1% of range + 0.2% of value) |
Relative Accuracy | ±0.006% |
Bandwidth | DC to 95 - 175 MHz (typical, depending on range) |
Input Filters | 3-pole, selectable: None, 30 MHz, 60 MHz |
SFDR | 83 dB, 1 MHz input (180 MS/s, 50 Ohm, 4 Vpp diff) |
THD | 85 dB, 1 MHz input 81 dB, 10 MHz input (180 MS/s, 50 Ohm, 4 Vpp diff) |
SNR | 69 dB, f-in=1 MHz, DC to 80 MHz BW 67 dB, f-in= 10 MHz, DC to 80 MHz BW (180 MS/s, 50 Ohm, 4 Vpp diff) |
Triggering |
---|
Connector | Front panel SMB |
Impedance | 1k Ohm nominal |
Threshold Level | 1.02 V, ±5% |
Trigger Hysteresis | 60 mV, typical |
Max Input Level | -0.5 V to + 5.5 V |
Triggering Sources | Front panel, PXI trigger 0 -7, PXI Star trigger, software trigger, input signal |
Modes | Positive / negative level or edge, Positive / negative edge continuous |
External Clock |
---|
Connector | Front panel SMB |
Input Impedance | 50 Ohm nominal |
Input Frequency Range | DC to 945 MHz (for direct clocking), 10 MHz as PLL reference |
Threshold Level | 1.02 V, ±5% |
Hysteresis | 60 mV, typical |
General |
---|
Current Consumption (Maximum) | +5 V @ 2.3 A +12 V @ 10 mA -12 V @ 110 mA +3.3 V @ 1.8 A |
Calibration | Reference voltage: manual, 12 months A/D converters: Auto cal, 3 months |
Weight | Approx. 0.55 lbs |
Size | 3U, single slot |
Operating Temperature | 0 °C to +50 °C |
Storage Temperature | 0 °C to +70 °C |
Humidity | 10% to 80% (Non-Condensing) |
Safety | EN61010-1:2001 |
CE Labeled | Yes EN61000-6-1:2001, EN55011:1998 |
Note: Specifications are subject to change without notice.
Downloads for GX2482 Series
GX2482DS.pdf
Feb 21, 2023
version: A
215.96 KB
GX2482xUG.pdf
May 1, 2020
version: 1
1.43 MB
GX2482_pa72.exe
May 24, 2016
version: 1.2
13.11 MB
Download our PXI Catalog
Products similar to GX2482 Series
- GC2200 Series - Time Interval Counter Card
- GX3216 Series - 16-Bit Multi-Function cPCI Card with A/D, D/A and Digital I/O Channels
- GX3232 Series - 16-Bit Multi-Function with A/D, D/A and Digital I/O Channels cPCI Cards
- GX3788 - High-Performance, FPGA Multi-Function PXI Card
Order GX2482 Series and Related Products
To order call
1-888-837-8297
or order on-line via the form below. Prices are specified for
USA
destination orders. Prices are noted in USD.
Import duties, taxes, and charges are not included in the item price.