Gx5731GetExtTriggerToPxiTriggerLine

Purpose

Returns the connections for the specified External Trigger toPxi Trigger line.

Syntax

Gx5731GetExtTriggerToPxiTriggerLine (nHandle, pnExtTrigToXTrigLine, pbMode, pnStatus)

Parameters

Name
Type
Description
nHandle
SHORT
Handle to a GX5731 board.
nExtTrigToXTrigLine
SHORT
 
External Trigger to Pxi Trigger Line numbers are:
0 GX5731_PXI_TRIGGER_LINE0: External Trigger 0
1 GX5731_PXI_TRIGGER_LINE1: External Trigger 1
2 GX5731_PXI_TRIGGER_LINE2: External Trigger 2
3 GX5731_PXI_TRIGGER_LINE3: External Trigger 3
4 GX5731_PXI_TRIGGER_LINE4: External Trigger 4
5 GX5731_PXI_TRIGGER_LINE5: External Trigger 5
6 GX5731_PXI_TRIGGER_LINE6: External Trigger 6
7 GX5731_PXI_TRIGGER_LINE7: External Trigger 7
bMode
BOOL
PXI trigger line mode are:
0 GX5731I_XTRIGGER_LINE_DISCONNECTED: PXI trigger line is disconnected.
1 GX5733_XTRIGGER_LINE_CONNECTED: PXI trigger line is Connected
pnStatus
 
PSHORT
Returned status: 0 on success, negative number on failure.

Comments

Use the Gx5731SetExtTriggerToPxiTriggerBusto set External Trigger lines can only be connected to their corresponding Pxi Triggers lines number.

Example

The following example returns External Triggers lines 2 to Pxi Triggers line 2 connection:

 

SHORT nStatus;

BOOL bMode;

 

Gx5731GetExtTriggerToPxiTriggerLine(nHandle, GX5731_EXT_TRIGGER_LINE2, bMode, pnStatus)

 

See Also

Gx5731SetExtTriggerToPxiTriggerLine, Gx5731SetExtTriggerToPxiTriggerBus, Gx5731GetExtTriggerToPxiTriggerLine, Gx5731SetStrobeToPxiTriggerBusState