The GX7310R is a model in the GX7300 series of 20-slot, 3U PXI chassis. [1] The GX7300 series is designed for applications such as automatic test equipment (ATE), data acquisition, process control, production test, scientific applications, and industrial systems. [1, 3]
Here's what is known about the GX7310 and related models:
GX7310:
It is a 3U PXI chassis. [1] It has 20 slots. [1] It weighs 30 lbs. [1] Its dimensions are 4U (7") H x 17.6" W x 16" D. [1] It uses four 65 CFM fans for system cooling. [1] It has a total available DC power of 755 watts. [1] DC current: +5 V (60 A max), +3.3 V (40 A max), +12 V (35 A max), -12 V (5 A max). [1]
GX7300 Series (General): The 3U form factor allows for a compact test system. [1] It can use both PXI and Compact PCI 3U modules. [1] The GX7300, GX7310, GX7302 and GX7312 models have a total of 755W of system power. [1] Forced-air cooling is provided by four 65 CFM fans. [1] Operating temperature: 0 °C to +50 °C. [1] Storage temperature: -20 °C to +60 °C. [1]
Other Models in the GX7300 Series: GX7300C and GX7300CR are master chassis with DVD-RW and hard disk drives. [1] GX7310C and GX7310CR are slave chassis for use with PXI Remote Controllers. [1] GX7305 and GX7315 have a high capacity, 1600 watt system power configuration. [1] GX7302C has an integrated Cable Tray & a Hinged front panel for Mass Interconnect. [1]It is important to note that specifications are subject to change. [1, 3]
- 20 Slot, 3U PXI Chassis - GX7300 Series
- GX7000B SERIES
- PXI Controller, 3U i7 Quad-core, 2.8 GHz cPCI Embedded Controller | Marvin Test Solutions, Inc.
Learn more about our Privacy Policy and Terms of Use. OK.
Separate fan for system power supply. Integrated temperature monitoring via an onboard microcontroller with audible and software notification when preset temperature limits are exceeded.
Applications Automatic Test Equipment (ATE) Data Acquisition Process Control Production Test Industrial Systems Portable Systems GX7939 Specifications Processor and Memory CPU Intel® Core® i i7-1185GRE Quad Core 2.8 GHz Processor, 12 MB cache Main Memory 32 GB...
The virtual panel can be used to interactively set /display shutdown and alarm conditions based on defined temperature levels. In addition, defined warning and alarm limits can the saved or recalled or optionally, the use of factory setting can be invoked.
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
Dedicated 50 CFM fan for power supply cooling. PXI Triggers Slots: 2 - 8 Number: 8 PXI Star Trigger Slots: 2 - 8 Dedicated, low skew Star trigger connecting slots 3 - 8 to slot 2, the PXI system timing slot PXI Clock and Synchronization Resources Integrated 10...
Connection to the DVD-RW drive and hard drive is via the controller's internal I/O interface. The controller's front panel I/O is provided with a factory default configuration and is fully functional in any PXI or cPCI chassis.
Slots 3-15 support the PXI Star Trigger and any PXI or cPCI instrument. Slots 16-20 accommodate PXI or cPCI instruments without the Star Trigger. 6U PXI SMART CHASSIS – KEy FEATURES • 20 slots supporting one 6U or 3U (embedded or remote) PXI controller and 19 ...
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
Applications Automatic Test Equipment (ATE) Data Acquisition Process Control Production Test Industrial Systems Portable Systems GX7936 Specifications Processor and Memory CPU Intel® Core® i7-2715QE 2.1 GHz Processor 6 MB cache 1066 / 1333 / 1600 MHz memory bu...
Connection to the DVD-RW drive and hard drive is via the controller's internal I/O interface. The controller's front panel I/O is provided with a factory default configuration and is fully functional in any PXI or cPCI chassis.
Applications Automatic Test Equipment (ATE) Data Acquisition Process Control Production Test Industrial Systems Portable Systems GX7938 Specifications Processor and Memory CPU Intel® Core® i i7-3615QE, Quad Core 2.3 GHz Processor, 12 MB Cache Main Memory 32 GB...
Applications Automatic Test Equipment (ATE) Data Acquisition Process Control Production Test Industrial Systems Portable Systems GX7938 Specifications Processor and Memory CPU Intel® Core® i i7-3615QE, Quad Core 2.3 GHz Processor, 12 MB Cache Main Memory 32 GB...
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
There are 56 Digital I/O channels, channel's direction control is set in groups of 4 channels, eg channels 0-3, channels 4-7, etc. Any group of channels can be programmed to be all in or all out.
Applications Automatic Test Equipment (ATE) Data Acquisition Process Control Production Test Industrial Systems Portable Systems GX7936 Specifications Processor and Memory CPU Intel® Core® i7-2715QE 2.1 GHz Processor 6 MB cache 1066 / 1333 / 1600 MHz memory bu...
The virtual panel provides a way to control, configure and display the smart chassis' features, including temperature monitoring, trigger line mapping, and power supply voltage monitoring.
It is a 3U PXI instrument card that can be used for general data acquisition, process control, Automatic Test Equipment (ATE), and functional test applications.
There are 56 Digital I/O channels, channel's direction control is set in groups of 4 channels, eg channels 0-3, channels 4-7, etc. Any group of channels can be programmed to be all in or all out.
•Cable tray, recessed card cage and top / bottom access to facilitate cable management and routing •Wide selection of direct access kits (DAK) and connectors for high density and high current signal interface applications •20 slot PXI chassis supporting a 6U (...
The card provides 80 LVDS transceiver channels. Each channel includes a 100 ohm termination. Programming and Software The board is supplied with the GXFPGA library, a software package that includes a virtual instrument panel, and a Windows 32/64-bit DLL driver...